ORGANOPHOSPHORUS PESTICIDES (LOW LEVEL)

Code: PE1377-1.2ML D2-231

Application

Organophosphorus Pesticides (Low Level) proficiency testing material is used to test the pesticides analyte concentration in drinking water samples.Have any quest...


read more

Your Price
€169.53 1.2ML
€208.52 inc. VAT

Application

Organophosphorus Pesticides (Low Level) proficiency testing material is used to test the pesticides analyte concentration in drinking water samples.Have any questions? Explore our FAQs.For more information on this product, please contact PT Service Team..

Features and Benefits

We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.Our proficiency testing (PT) program is a benchmark to: provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process provide a comparison of performance with that of other laboratories, nationally and internationally test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems provide an independent evaluation of laboratory performance demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality

General description

Organophosphorus Pesticides (Low Level) - PT proficiency testing material is produced in accordance with ISO/IEC 17043:2010. The PT portfolio allows our test components to offer significant performance data to monitor and prove competency to customers, accreditation bodies or both.Supelco® is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. Most water PT samples are available as concentrates or ready-to-use volumes giving the end-user flexibility in selecting samples that will fit their exact needs.These samples are typically provided in duplicate for use in case of lab mishap, for QC purposes or to analyze multiple methods.Type of PT Scheme: Water analysis - Water Supply (WS)Matrix: Water Supply/Drinking waterAnalyte/s: Values of analytes vary lot to lot. All information regarding the use of Organophosphorus Pesticides - (Low Level) Proficiency Testing standard can be found in the reporting packet which will be available to download at PT Portal.

Legal Information

Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany

Other Notes

Are you new to Supelco® Proficiency TestingͰ Be sure to register your account details in the PT Portal before placing your order.This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at [email protected] placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.Proficiency testing samples are presented as single blind. No values for the samples are released unti the testing period concludes.Proficiency Testing Schedule (2022-2023)Drinking WaterWS22-2 March 23 - May 6, 2022WS23-2 March22 – May 5, 2023Quick-Turn Study (on demand proficiency test that is offereddepending on lot availability)

Preparation Note

DescriptionRandomly contains a minimum 80% of the analytes listed. This PT sample is provided as a concentrate requiring dilution into reagent water. Can be evaluated for each analyte listed on the report form. If there are any analytes in the above list you wish not to be evaluated for, leave the associated line blank on the report form. Packaged as a 1.2 mL concentrate. The solvent for this sample is acetone. The PT sample is not preserved. The sample must be stored at 4 °C.Sample preparationPreparation Instructions Allow the ampule concentrate to equilibrate to room temperature. Fill a 1000 mL Class A Volumetric Flask with 900 mL of organic free reagent water. Open the ampule and pipet exactly 1.0 mL of the concentrate into the flask. Fill to volume and mix well. This represents the sample for analysis.

Storage and Stability

Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.

application(s)environmental
concentrationin acetone
formatmatrix material
packagingampule of 2 × 1.2 mL
Quality Level100
storage temp.2-8°C
Hazard Class3
Un Number1993
Pack GroupII
This product has met the following criteria to qualify for the following awards:



PROCEED TO CHECKOUT

HAVE AN ACCOUNT? LOGIN


GUEST CHECKOUT

Proceed as a guest. You will have the option to register to access exclusive pricing and stock availability features after checkout.